Vector Network Analyzers – Multi Port
DISCONTINUED
T-Series high performance multi-port VNAs have a wide dynamic range, low noise level and low trace noise.
Data Sheet VNA Measurements Sales Offices eContact us
Features
- Multi port: 4-10 ports
- Independent sources, measurement and reference receivers for each port
- Wide dynamic range: 123 dB typ
- Frequency range: 100 MHz to 4 GHz
- Low trace noise: 0.002 dB rms
- IF bandwidth: 10 Hz to 100 kHz
- VISA remote control commands
When testing times are of the essence and accuracy is paramount, T-Series Multiport Vector Network Analyzers (VNAs) , designed by Transcom, are the answer. T58XX VNAs can carry out parallel tests with DUTs of up to 10 ports or test multiple DUTs simultaneously.
Each port has an independent source, measurement receiver and reference receiver, making this
VNA fast, really fast. Individual DUTs can be assigned individual external monitors, for unambiguous
test results. T-Series Multi Port VNAs offer VISA remote commands and can be easily integrated in
CAM environments.
T- Series Multiport VNA Models
Model |
Frequency Range |
Type
|
Measurement
|
System
|
T5840A-P04 | 100 MHz to 4.0 GHz | Bench-top | 4 | Stand alone |
T5840A-P05 | 100 MHz to 4.0 GHz | Bench-top | 5 | Stand alone |
T5840A-P06 | 100 MHz to 4.0 GHz | Bench-top | 6 | Stand alone |
T5840A-P07 | 100 MHz to 4.0 GHz | Bench-top | 7 | Stand alone |
T5840A-P08 | 100 MHz to 4.0 GHz | Bench-top | 8 | Stand alone |
T5840A-P09 | 100 MHz to 4.0 GHz | Bench-top | 9 | Stand alone |
T5840A-P10 | 100 MHz to 4.0 GHz | Bench-top | 10 | Stand alone |
Measurement Range |
|
Impedance | 50 Ω, 75 Ω ( with 50 to 75 Ohm pad) |
Test Port Connectors | N-type (f) |
Number of Test Ports | 4 – 10 (see table) |
Frequency Range | 100 MHz to 4.0 GHz ( see table) |
Full CW frequency Accuracy | ±5×10-6 |
Frequency Resolution | 1 Hz |
Measurement Points | 2 to 10001 |
Measurement Bandwidths | 10 Hz to 100 kHz |
Dynamic Range | >123 dB (100 MHz to 4.0 GHz, IFBW=10Hz) > 95 dB (100 MHz to 4.0 GHz, IFBW=3 kHz) |
Measurement Accuracy |
|
Trace Noise Magnitude: power | 0.002 dBm RMA (typ.) |
Trace Noise Magnitude: Phase | 0.02 ° RMS (typ.) |
Temperature Dependence | Magnitude: 0.006 dB / °C Phase: 0.15 deg / °C |
Power Accuracy | +/- 1.0 dB |
Test Port |
|
Power Range | -50 dBm to +10 dBm |
Power Resolution | 0.05 dB |
Max power / voltage | 26 dBm / +/- 35V |
Effective System Data (1) |
|
Effective directivity | 45 dB |
Effective source match | 40 dB |
(1) applies over the temperature range of 23°C +/- 5°C after 40 minutes of warming up. with less than 1°C deviation from the full 2 port calibration temperature, at output power of -5dBm and IF bandwidth 10 Hz |
Measurement Speed |
|
Measurement time per port | 200 us |
Port to receiver port switch time | <10 ms |
General Data |
|
Display | 11.6 inch LCD touch screen |
USB connectors | 8 (2 x USB 3.0, 6 x USB 2.0) |
LAN connectors | 10/100/1000 Base Ethernet, 8-pin configuration |
Video connectors | DVI / HDMI |
Operating Temperature | +5° to +40°C ( 41 °F to 104 °F) |
Storage Temperature | -45° to +60°C ( – 49 °F to 140 °F) |
Humidity (max.) | 90 % (25°C) |
Atmospheric pressure | 84 to 106.7 kPa |
Power Supply | 220 VAC +/- 10%, 50 Hz 115 VAC +/- 10%, 60 Hz |
Power Consumption | 260 W |
Dimensions ( mm / in) | 440 x 267 x 360 / 17.3 x 10.1 x 14.2 |
Weight (kg / lbs) | 12.5 to 15.5 kg / 27.5 to 34.0 lbs |
Calibration Interval | 3 years |
Specifications subject to change without further notification.